1.
Langenbecks Arch Surg ; 409(1): 147, 2024 May 02.
Artigo em Inglês | MEDLINE | ID: mdl-38695955

RESUMO

PURPOSE: To investigate the accuracy of laser speckle flowgraphy (LSFG), a noninvasive method for the quantitative evaluation of blood flow using mean blur rate (MBR) as a blood flow parameter in the assessment of bowel blood perfusion compared to indocyanine green fluorescence angiography (ICG-FA). METHODS: We enrolled 46 patients who underwent left-sided colorectal surgery. LSFG and ICG-FA were applied to assess blood bowel perfusion, with MBR and luminance as parameters, respectively. In both measurement methods, the position where the parameter suddenly decreased was defined as the blood flow boundary line. Subsequently, the blood flow boundaries created after processing the blood vessels flowing into the intestinal tract were determined using LSFG and ICG-FA, and concordance between the two was examined. Blood flow boundaries were visually identified using color tone changes on a color map created based on MBR in LSFG and using differences in luminance in ICG-FA. The distances between the transection line and blood flow boundaries determined using each method were compared. RESULTS: The location of blood flow boundaries matched in 65% (30/46) of cases. Although locations differed in the remaining 35% (16/46), all were located on the anal side near the transection line, and the difference was not clinically significant. The average distances between the transection line and blood flow boundary were 2.76 (SD = 3.25) and 3.71 (SD = 4.26) mm, respectively. There was no statistically significant difference between the two groups (p = 0.38). CONCLUSION: LSFG was shown to have comparable accuracy to ICG-FA, and may be useful for evaluating bowel perfusion.


Assuntos
Corantes , Angiofluoresceinografia , Verde de Indocianina , Humanos , Feminino , Angiofluoresceinografia/métodos , Masculino , Idoso , Pessoa de Meia-Idade , Imagem de Contraste de Manchas a Laser , Idoso de 80 Anos ou mais , Fluxo Sanguíneo Regional/fisiologia , Adulto , Intestinos/irrigação sanguínea , Velocidade do Fluxo Sanguíneo/fisiologia , Neoplasias Colorretais/cirurgia
2.
Jpn J Ophthalmol ; 68(3): 211-215, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38609716

RESUMO

PURPOSE: To investigate the association between the arm-to-choroidal circulation time (ACT) on indocyanine green angiography (IA) and clinical profile in patients with polypoidal choroidal vasculopathy (PCV). STUDY DESIGN: Single-center retrospective study. METHODS: We included 38 eyes of 38 patients with PCV diagnosed using multimodal imaging and did not undergo previous treatment. All patients were treated with monthly aflibercept injections for 3 months and treat-and-extend regimens for the subsequent 12 months. Posterior vortex vein ACT was assessed on the first visit using Heidelberg IA. The patients were divided into two groups: ACT ≥20 s (L group; eight eyes) and ACT <20 s (S group; 30 eyes). The clinical profiles before and after treatment were analyzed to assess associations with ACT. RESULTS: The mean ACT was 16.39±3.3 s (L group: 21.25±1.49 s, women:men=2:6, mean age: 77.3±6.5 years; S group: 15.10±2.17 s, women:men=7:23, mean age: 75.5±6.9 years). No significant difference was observed in the mean subfoveal choroidal thickness between the L and the S groups (176±75 µm vs. 230±79 µm, P=0.10). However, there were significant differences between the L and S groups in retinal fluid accumulation and hemorrhage recurrence (eight/eight eyes, 100% vs. 13/30 eyes, 43%, P<0.001), mean aflibercept injections (8.8±1.6 vs. 7.0±1.6, P<0.01) during the 12-month period, and the number of polypoidal lesions (1.8±0.7 vs. 1.3±0.5, P<0.05). CONCLUSION: Patients with PCV and ACT >20 s are more likely to experience exudative change recurrence in the retina during treatment because they have more polypoidal lesions.


Assuntos
Corioide , Angiofluoresceinografia , Fundo de Olho , Injeções Intravítreas , Pólipos , Receptores de Fatores de Crescimento do Endotélio Vascular , Proteínas Recombinantes de Fusão , Tomografia de Coerência Óptica , Acuidade Visual , Humanos , Feminino , Masculino , Estudos Retrospectivos , Corioide/irrigação sanguínea , Corioide/diagnóstico por imagem , Idoso , Angiofluoresceinografia/métodos , Tomografia de Coerência Óptica/métodos , Pólipos/diagnóstico , Pólipos/tratamento farmacológico , Pólipos/fisiopatologia , Receptores de Fatores de Crescimento do Endotélio Vascular/uso terapêutico , Receptores de Fatores de Crescimento do Endotélio Vascular/administração & dosagem , Proteínas Recombinantes de Fusão/administração & dosagem , Proteínas Recombinantes de Fusão/uso terapêutico , Verde de Indocianina/administração & dosagem , Seguimentos , Neovascularização de Coroide/tratamento farmacológico , Neovascularização de Coroide/diagnóstico , Neovascularização de Coroide/fisiopatologia , Corantes/administração & dosagem , Idoso de 80 Anos ou mais , Doenças da Coroide/diagnóstico , Doenças da Coroide/tratamento farmacológico , Doenças da Coroide/fisiopatologia , Inibidores da Angiogênese/administração & dosagem , Inibidores da Angiogênese/uso terapêutico , Fluxo Sanguíneo Regional/fisiologia , Imagem Multimodal , Velocidade do Fluxo Sanguíneo/fisiologia , Vasculopatia Polipoidal da Coroide
3.
Eur Radiol Exp ; 8(1): 45, 2024 Mar 13.
Artigo em Inglês | MEDLINE | ID: mdl-38472565

RESUMO

BACKGROUND: Phase-contrast magnetic resonance imaging (PC-MRI) quantifies blood flow and velocity noninvasively. Challenges arise in neurovascular disorders due to small vessels. We evaluated the impact of voxel size, number of signal averages (NSA), and velocity encoding (VENC) on PC-MRI measurement accuracy and precision in a small-lumen vessel phantom. METHODS: We constructed an in vitro model with a constant flow rate using a 2.2-mm inner diameter plastic tube. A reservoir with a weight scale and timer was used as standard reference. Gradient-echo T1 weighted PC-MRI sequence was performed on a 3-T scanner with varying voxel size (2.5, 5.0, 7.5 mm3), NSA (1, 2, 3), and VENC (200, 300, 400 cm/s). We repeated measurements nine times per setting, calculating mean flow rate, maximum velocity, and least detectable difference (LDD). RESULTS: PC-MRI flow measurements were higher than standard reference values (mean ranging from 7.3 to 9.5 mL/s compared with 6.6 mL/s). Decreased voxel size improved accuracy, reducing flow rate measurements from 9.5 to 7.3 mL/s. The LDD for flow rate and velocity varied between 1 and 5%. The LDD for flow rate decreased with increased voxel size and NSA (p = 0.033 and 0.042). The LDD for velocity decreased with increased voxel size (p < 10-16). No change was observed when VENC varied. CONCLUSIONS: PC-MRI overestimated flow. However, it has high precision in a small-vessel phantom with constant flow rate. Improved accuracy was obtained with increasing spatial resolution (smaller voxels). Improved precision was obtained with increasing signal-to-noise ratio (larger voxels and/or higher NSA). RELEVANCE STATEMENT: Phase-contrast MRI is clinically used in large vessels. To further investigate the possibility of using phase-contrast MRI for smaller intracranial vessels in neurovascular disorders, we need to understand how acquisition parameters affect phase-contrast MRI-measured flow rate and velocity in small vessels. KEY POINTS: • PC-MRI measures flow and velocity in a small lumen phantom with high precision but overestimates flow rate. • The precision of PC-MRI measurements matches the precision of standard reference for flow rate measurements. • Optimizing PC-MRI settings can enhance accuracy and precision in flow rate and velocity measurements.


Assuntos
Imageamento por Ressonância Magnética , Velocidade do Fluxo Sanguíneo/fisiologia , Imageamento por Ressonância Magnética/métodos , Razão Sinal-Ruído , Imagens de Fantasmas , Reprodutibilidade dos Testes
4.
Am J Physiol Heart Circ Physiol ; 326(5): H1105-H1116, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38391313

RESUMO

Whether cerebral sympathetic-mediated vasomotor control can be modulated by local brain activity remains unknown. This study tested the hypothesis that the application or removal of a cognitive task during a cold pressor test (CPT) would attenuate and restore decreases in cerebrovascular conductance (CVC), respectively. Middle cerebral artery blood velocity (transcranial Doppler) and mean arterial pressure (finger photoplethysmography) were examined in healthy adults (n = 16; 8 females and 8 males) who completed a control CPT, followed by a CPT coupled with a cognitive task administered either 1) 30 s after the onset of the CPT and for the duration of the CPT or 2) at the onset of the CPT and terminated 30 s before the end of the CPT (condition order was counterbalanced). The major finding was that the CPT decreased the index of CVC, and such decreases were abolished when a cognitive task was completed concurrently and restored when the cognitive task was removed. As a secondary experiment, vasomotor interactions between sympathetic transduction pathways (α1-adrenergic and Y1-peptidergic) and compounds implicated in cerebral blood flow control [adenosine, and adenosine triphosphate (ATP)] were explored in isolated porcine cerebral arteries (wire myography). The data reveal α1-receptor agonism potentiated vasorelaxation modestly in response to adenosine, and preexposure to ATP attenuated contractile responses to α1-agonism. Overall, the data suggest a cognitive task attenuates decreases in CVC during sympathoexcitation, possibly related to an interaction between purinergic and α1-adrenergic signaling pathways.NEW & NOTEWORTHY The present study demonstrates that the cerebrovascular conductance index decreases during sympathoexcitation and this response can be positively and negatively modulated by the application or withdrawal of a nonexercise cognitive task. Furthermore, isolated vessel experiments reveal that cerebral α1-adrenergic agonism potentiates adenosine-mediated vasorelaxation and ATP attenuates α1-adrenergic-mediated vasocontraction.


Assuntos
Trifosfato de Adenosina , Simpatolíticos , Adulto , Masculino , Feminino , Humanos , Animais , Suínos , Velocidade do Fluxo Sanguíneo/fisiologia , Adrenérgicos , Adenosina/farmacologia , Circulação Cerebrovascular/fisiologia , Pressão Sanguínea/fisiologia , Temperatura Baixa
5.
BMC Ophthalmol ; 24(1): 89, 2024 Feb 27.
Artigo em Inglês | MEDLINE | ID: mdl-38413884

RESUMO

BACKGROUND: To evaluate the changes in retrobulbar circulation after strabismus surgery and to assess the relationship of these changes with choroidal thickness (CT). METHODS: This prospective study included 26 eyes of 26 patients who underwent strabismus surgery and 15 eyes of 15 healthy individuals as control group. The patients who had single horizontal muscle surgery were included in Group 1 (n = 14); and those who had surgery on both horizontal muscles were included in Group 2 (n = 12). Peak systolic velocity (PSV), end-diastolic velocity (EDV), resistive index (RI) and pulsatility index (PI) of ophthalmic artery (OA), posterior ciliary artery (PCA), and central retinal artery (CRA) were measured using Color Doppler Ultrasonography. Subfoveal CT was measured via Optical Coherence Tomography. All measurements were obtained preoperatively, at 1st week and 1st month after surgery. RESULTS: There were no differences regarding preoperative blood flow velocity parameters among the groups. OA RI increased significantly at 1st week and 1st month after surgery in Group 1 and 2 (P = 0.029 and P = 0.045, respectively). There was a significant increase in PCA PSV at 1st week in Group 1 (P = 0.002). There was no difference between the mean preoperative and postoperative CT among the 3 groups. A negative correlation between the percentage changes of CT and CRA EDV was found in Group 2 (P = 0.011). CONCLUSION: Single and double horizontal rectus muscle surgery have a measurable effect on retrobulbar hemodynamics but these changes do not correlate with CT.


Assuntos
Artéria Retiniana , Estrabismo , Humanos , Estudos Prospectivos , Órbita , Hemodinâmica/fisiologia , Artéria Retiniana/diagnóstico por imagem , Artéria Oftálmica , Velocidade do Fluxo Sanguíneo/fisiologia , Corioide , Ultrassonografia Doppler em Cores/métodos , Estrabismo/cirurgia
6.
J Plast Reconstr Aesthet Surg ; 91: 111-118, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38412601

RESUMO

BACKGROUND: There is a lack of data regarding the baseline hemodynamic blood flow parameters of the wrist and digits. Therefore, we aimed to quantify the digital and radial artery blood flow parameters using ultrasound and assess the influence of patient characteristics on hemodynamics. METHODS: We analyzed ultrasonographic data from 25 patients (50 hands) between October 2019 and December 2021. Variables of interest included dimensions of the radial artery and index finger (IF) ulnar and radial digital arteries at the palmodigital crease and their corresponding flow parameters. We compared variables among men and women and patients with and without diabetes using Wilcoxon Rank Sum test. RESULTS: Our cohort consisted of 18 women (36 hands) and three participants with diabetes (six hands). The mean diameter of the IF radial digital artery was 7 mm, and that of the ulnar digital artery was 10 mm. The average peak systolic velocity for the radial digital artery was 21.31 cm/sec, and for the ulnar digital artery, it was 30.03 cm/sec. Comparing men and women, the only significant difference found was in the time-averaged mean velocity for the ulnar digital artery (men:5.66 cm/sec vs. women:9.68 cm/sec, P = 0.02) and volume of flow for the ulnar digital artery (men:10.87cc/min vs. women:18.58cc/min, P = 0.03). We found no differences in blood flow parameters comparing participants with and without diabetes. CONCLUSION: These data provide a baseline measurement of digital flow hemodynamics that can be used in future studies to model vascular flow after replantation.


Assuntos
Diabetes Mellitus , Artéria Ulnar , Masculino , Humanos , Feminino , Artéria Ulnar/diagnóstico por imagem , Hemodinâmica , Artéria Radial/diagnóstico por imagem , Punho , Velocidade do Fluxo Sanguíneo/fisiologia
7.
Photodiagnosis Photodyn Ther ; 45: 103985, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38246214

RESUMO

BACKGROUND: To evaluate the choroidal thickness and retrobulbar hemodynamic parameters in polycythemia vera (PV) patients in comparison with healthy individuals, and to investigate the relationship of these values with blood hematocrit levels. METHODS: This prospective study included the 35 eyes of 35 PV patients and the 30 eyes of 30 healthy individuals. Choroidal thickness was measured at the subfoveal area and at 500 µm intervals nasal and temporal to the fovea up to a distance of 1500 µm. Color Doppler ultrasonography (CDU) was used to evaluate the retrobulbar vessels. Complete blood count values were recorded. RESULTS: Choroidal thickness was found to be significantly lower in the PV group than in the control group at the subfoveal, nasal 500, and temporal 500 and 1000 µm measurement points (p = 0.01, p = 0.011, p = 0.04, p = 0.045, respectively). The central retinal artery (CRA) peak systolic velocity (PSV) and end diastolic velocity (EDV) values and the ophthalmic artery (OA) PSV value were significantly lower in the PV group than in the control group (p < 0.001, p < 0.001, p = 0.019, respectively). No significant difference was present between the groups in terms of CRA and OA resistive index (RI) and pulsatile index (PI) values (p = 0.388, p = 0.564, p = 0.897, p = 0.693, respectively). A negative correlation was found between the blood hematocrit levels and the subfoveal, nasal 500 µm, and temporal 500 µm choroidal thickness measurements and the CRA PSV and EDV and the OA PSV values. CONCLUSIONS: PV may cause microvascular changes and lead to ocular vascular complications by affecting the choroidal and retrobulbar blood flow.


Assuntos
Fotoquimioterapia , Policitemia Vera , Humanos , Estudos Prospectivos , Velocidade do Fluxo Sanguíneo/fisiologia , Fotoquimioterapia/métodos , Fármacos Fotossensibilizantes , Hemodinâmica , Corioide/diagnóstico por imagem
8.
BMC Pregnancy Childbirth ; 24(1): 60, 2024 Jan 12.
Artigo em Inglês | MEDLINE | ID: mdl-38216901

RESUMO

BACKGROUND: Present evidence suggests that the Doppler ultrasonographic indices, such as carotid artery blood flow (CABF) and velocity time integral (VTI), had the ability to predict fluid responsiveness in non-obstetric patients. The purpose of this study was to assess their capacity to predict fluid responsiveness in spontaneous breathing parturients undergoing caesarean section and to determine the effect of detecting and management of hypovolemia (fluid responsiveness) on the incidence of hypotension after anaesthesia. METHODS: A total of 72 full term singleton parturients undergoing elective caesarean section were enrolled in this study. CABF, VTI, and hemodynamic parameters were recorded before and after fluid challenge and assessed by carotid artery ultrasonography. Fluid responsiveness was defined as an increase in stroke volume index (SVI) of 15% or more after the fluid challenge. RESULTS: Thirty-one (43%) patients were fluid responders. The area under the ROC curve to predict fluid responsiveness for CABF and VTI were 0.803 (95% CI, 0.701-0.905) and 0.821 (95% CI, 0.720-0.922). The optimal cut-off values of CABF and VTI for fluid responsiveness was 175.9 ml/min (sensitivity of 74.0%; specificity of 78.0%) and 8.7 cm/s (sensitivity of 67.0%; specificity of 90.0%). The grey zone for CABF and VTI were 114.2-175.9 ml/min and 6.8-8.7 cm/s. The incidence of hypotension after the combined spinal-epidural anaesthesia (CSEA) was significantly higher in the Responders group 25.8% (8/31) than in the Non-Responders group 17.1(7/41) (P < 0.001). The total incidence of hypotension after CSEA of the two groups was 20.8% (15/72). CONCLUSIONS: Ultrasound evaluation of CABF and VTI seem to be the feasible parameters to predict fluid responsiveness in parturients undergoing elective caesarean section and detecting and management of hypovolemia (fluid responsiveness) could significantly decrease incidence of hypotension after anaesthesia. TRIAL REGISTRATION: The trial was registered at the Chinese Clinical Trial Registry (ChiCTR) ( www.chictr.org ), registration number was ChiCTR1900022327 (The website link: https://www.chictr.org.cn/showproj.html?proj=37271 ) and the date of trial registration was in April 5, 2019. This study was performed in accordance with the Declaration of Helsinki and approved by the Research Ethics Committee of Women's Hospital, Zhejiang University School of Medicine (20,180,120).


Assuntos
Cesárea , Hipotensão , Humanos , Feminino , Gravidez , Cesárea/efeitos adversos , Hipovolemia/etiologia , Estudos Prospectivos , Hemodinâmica/fisiologia , Artérias Carótidas/diagnóstico por imagem , Hipotensão/etiologia , Ultrassonografia das Artérias Carótidas , Hidratação , Velocidade do Fluxo Sanguíneo/fisiologia
9.
Eur J Ophthalmol ; 34(1): 95-101, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37218176

RESUMO

BACKGROUND/OBJECTIVES: Progression of retinopathy of prematurity (ROP) is associated with increased retinal blood flow velocities. We investigated changes of central retinal arterial and venous blood flow after intravitreal administration of bevacizumab. SUBJECTS/METHODS: Prospective observational study using serial ultrasound Doppler imaging in preterm infants with bevacizumab-treated ROP. Eyes were examined 1 [0-2] days before injection (median [interquartile range]), and at three time points after injection (1 [1-2] days, 6 [3-8] days, and 17 [9-28] days). Preterm infants with ROP stage 2 displaying spontaneous regression served as controls. RESULTS: In 21 eyes of 12 infants with bevacizumab-treated ROP, peak arterial systolic velocity declined from 13.6 [11.0-16.3] cm/s prior to intravitreal bevacizumab to 11.2 [9.4-13.9] cm/s, 10.6 [9.2-13.3] cm/s and 9.3 [8.2-11.0] cm/s at discharge (p = .002). There was also a decline of the arterial velocity time integral (from 3.1 [2.3-3.9] cm to 2.9 [2.4-3.5], 2.7 [2.3-3.2] cm and 2.2 [2.0-2.7], p = .021) and mean velocity in the central retinal vein (from 4.5 [3.6-5.8] cm/s to 3.7 [2.6-4.1] cm/s, 3.5 [3.0-4.3] cm/s, and 3.2 [2.8-4.6] cm/s, p = .012). Arterial end-diastolic velocity and resistance index remained unchanged. Blood flow velocities in bevacizumab-treated eyes examined before injection were significantly higher than those measured in untreated eyes that ultimately showed spontaneous regression of ROP. Sequential examinations in these controls did not reveal any declines of retinal blood flow velocities. CONCLUSION: Increased retinal arterial and venous blood flow velocities in infants with threshold ROP decline following intravitreal bevacizumab injection.


Assuntos
Retinopatia da Prematuridade , Lactente , Recém-Nascido , Humanos , Bevacizumab/uso terapêutico , Retinopatia da Prematuridade/diagnóstico , Retinopatia da Prematuridade/tratamento farmacológico , Recém-Nascido Prematuro , Inibidores da Angiogênese/uso terapêutico , Velocidade do Fluxo Sanguíneo/fisiologia , Remissão Espontânea , Fator A de Crescimento do Endotélio Vascular/farmacologia , Retina , Injeções Intravítreas , Idade Gestacional
10.
Acad Radiol ; 31(3): 929-938, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37714720

RESUMO

RATIONALE AND OBJECTIVES: To evaluate 4D Flow magnetic resonance imaging (MRI) sequences for quantitative flow measurements of the pelvic venous vasculature. MATERIALS AND METHODS: A prospective study of healthy volunteers was performed. After informed consent all subjects underwent 4D flow sequences at a 3 T MRI scanner with different isotropic resolution and different velocity encoding (Venc) settings: (sequence #1) voxel size (VS) 1.63 mm3, Venc 50 cm/s; (sequence #2) VS 1.63 mm3, Venc 100 cm/s and (sequence #3) VS 2.03 mm3, Venc 50 cm/s. Perfusion parameters were calculated for all venous vessel segments starting at the level of the inferior vena cava and extending caudally to the level of the common femoral vein. For reference, arterial flow was calculated using 1.63 mm3 isotropic resolution with a Venc of 100 cm/s. RESULTS: Ten healthy subjects (median age 28 years, interquartile range [IQR]: 26.25-28 years) were enrolled in this study. Median scanning time was 12:12 minutes (IQR 10:22-13:32 minutes) for sequence #1, 11:02 minutes (IQR 9:57-11:19 minutes) for sequence #2 and 6:10 minutes (IQR 5:44-6:47 minutes) for sequence #3. Flow measurements were derived from all sequences. The venous pelvic vasculature showed similar perfusion parameters compared to its arterial counterpart, for example the right common iliac arterial segment showed a perfusion of 8.32 ml/s (IQR: 6.94-10.68 ml/s) versus 7.29 ml/s (IQR: 4.70-8.90 ml/s) in the corresponding venous segment (P = 0.218). The venous flow measurements obtained from the three investigated sequences did not reveal significant differences. CONCLUSION: 4D Flow MRI is suitable for quantitative flow measurement of the venous pelvic vasculature. To reduce the scanning time without compromising quantitative results, the resolution can be decreased while increasing the Venc. This technique may be utilized in the future for the diagnosis and treatment response assessment of iliac vein compression syndromes.


Assuntos
Imageamento Tridimensional , Imageamento por Ressonância Magnética , Humanos , Adulto , Estudos Prospectivos , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Artérias , Velocidade do Fluxo Sanguíneo/fisiologia , Reprodutibilidade dos Testes
11.
Ultrasound Med Biol ; 50(3): 434-444, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-38143187

RESUMO

OBJECTIVE: Post-operative brain injury in neonates may result from disturbed cerebral perfusion, but accurate peri-operative monitoring is lacking. High-frame-rate (HFR) cerebral ultrasound could visualize and quantify flow in all detectable vessels using spectral Doppler; however, automated quantification in small vessels is challenging because of low signal amplitude. We have developed an automatic envelope detection algorithm for HFR pulsed wave spectral Doppler signals, enabling neonatal brain quantitative parameter maps during and after surgery. METHODS: HFR ultrasound data from high-risk neonatal surgeries were recorded with a custom HFR mode (frame rate = 1000 Hz) on a Zonare ZS3 system. A pulsed wave Doppler spectrogram was calculated for each pixel containing blood flow in the image, and spectral peak velocity was tracked using a max-likelihood estimation algorithm of signal and noise regions in the spectrogram, where the most likely cross-over point marks the blood flow velocity. The resulting peak systolic velocity (PSV), end-diastolic velocity (EDV) and resistivity index (RI) were compared with other detection schemes, manual tracking and RIs from regular pulsed wave Doppler measurements in 10 neonates. RESULTS: Envelope detection was successful in both high- and low-quality arterial and venous flow spectrograms. Our technique had the lowest root mean square error for EDV, PSV and RI (0.46 cm/s, 0.53 cm/s and 0.15, respectively) when compared with manual tracking. There was good agreement between the clinical pulsed wave Doppler RI and HFR measurement with a mean difference of 0.07. CONCLUSION: The max-likelihood algorithm is a promising approach to accurate, automated cerebral blood flow monitoring with HFR imaging in neonates.


Assuntos
Hemodinâmica , Ultrassonografia Doppler , Recém-Nascido , Humanos , Ultrassonografia , Ultrassonografia Doppler/métodos , Velocidade do Fluxo Sanguíneo/fisiologia , Encéfalo/diagnóstico por imagem , Algoritmos
12.
Med Sci Monit ; 29: e941958, 2023 Dec 10.
Artigo em Inglês | MEDLINE | ID: mdl-38071424

RESUMO

BACKGROUND Among patients with ICA stenosis, there are some cases with elevated, undisrupted, and diminished cerebral blood flow (CBF). The aim of this study was to assess the influence of ICA stenosis treatment on postoperative CBF changes in relation to preoperative CBF values. MATERIAL AND METHODS We qualified 58 patients ≥65 years old (28 males, 30 females, mean age 71.02±6.34 years) for surgical intervention due to symptomatic ≥70% ICA stenosis. In all patients, a flow volume in all extracranial arteries (internal carotid [ICA], external carotid [ECA], and vertebral arteries [VA]) was measured preoperatively and 2-3 days following the surgery. The CBF values were compared with the ones established for a healthy population of the same age. RESULTS Preoperatively, there were 3 subgroups of patients, comparing to healthy population: with elevated CBF - "significant compensation," with undisrupted CBF - "mild compensation," and with diminished CBF - "no compensation." Postoperatively, a significant CBF increase was observed in patients with preoperative "no" and "mild compensation" - 277.18±154.26 ml/min (P=0.0000001) and 221.56±98.8 ml/min (P=0.0000001). In a "significant compensation" group, there was no flow increase observed (CBF change of 2.57±58.5 ml/min, P=0.954) - a redistribution of flow was observed. CONCLUSIONS In patients with lower preoperative CBF values, surgical treatment caused a significant increase in global cerebral inflow, which was more prominent in patients with the lowest preoperative CBF. In patients with high preoperative CBF, surgical treatment resulted in a flow redistribution, but did not cause a CBF increase. Volumetric flow assessment in DUS can predict hemodynamic benefit from surgery in terms of CBF increase.


Assuntos
Estenose das Carótidas , Masculino , Feminino , Humanos , Pessoa de Meia-Idade , Idoso , Estenose das Carótidas/cirurgia , Artéria Carótida Interna/cirurgia , Constrição Patológica , Velocidade do Fluxo Sanguíneo/fisiologia , Circulação Cerebrovascular/fisiologia
13.
Sensors (Basel) ; 23(20)2023 Oct 16.
Artigo em Inglês | MEDLINE | ID: mdl-37896580

RESUMO

It is important to improve cerebrovascular health before the occurrence of cerebrovascular disease, as it has various aftereffects and a high recurrence rate, even with appropriate treatment. Various medical recommendations for preventing cerebrovascular diseases have been introduced, including smoking cessation, exercise, and diet. However, the effectiveness of these methods varies greatly from person to person, and their effects cannot be confirmed unless they are practiced over a long period. Therefore, there is a growing need to develop more quantitative methods that are applicable to the public to promote cerebrovascular health. Thus, in this study, we aimed to develop noninvasive and quantitative thermal stimulation techniques using ultrasound to improve cerebrovascular health and prevent cerebrovascular diseases. This study included 27 healthy adults in their 20s (14 males, 13 females). Thermal stimulation using therapeutic ultrasound at a frequency of 3 MHz was applied to the right sternocleidomastoid muscle in the supine posture for 2 min at four intensities (2.4, 5.1, 7.2, and 10.2 W/cm2). Diagnostic ultrasound was used to measure the peak systolic velocity (PSV), heart rate (HR), and pulse wave velocity (PWV) in the right common carotid artery (CCA), and the physiological changes were compared between intervention intensities. Compared to pre-intervention (preI), the PSV showed a significant increase during intervention (durI) at intensities of 7.2 W/cm2 and 10.2 W/cm2 (p = 0.010 and p = 0.021, respectively). Additionally, PWV showed a significant decrease for post-intervention (postI) at 7.2 W/cm2 and 10.2 W/cm2 (p = 0.036 and p = 0.035, respectively). However, the HR showed no significant differences at any of the intensities. The results demonstrate that an intervention at 3 MHz with an intensity of 7.2 W/cm2 or more can substantially increase cerebral blood flow and reduce arterial stiffness. Therefore, the use of therapeutic ultrasound of appropriate intensity is expected to improve the cerebral blood flow and reduce vascular stiffness to maintain cerebral blood flow at a certain level, which is closely related to the prevention and treatment of cerebrovascular diseases, thereby improving cerebrovascular health.


Assuntos
Transtornos Cerebrovasculares , Terapia por Ultrassom , Rigidez Vascular , Masculino , Adulto , Feminino , Humanos , Rigidez Vascular/fisiologia , Análise de Onda de Pulso , Circulação Cerebrovascular , Velocidade do Fluxo Sanguíneo/fisiologia
14.
Heart Surg Forum ; 26(3): E234-E239, 2023 May 31.
Artigo em Inglês | MEDLINE | ID: mdl-37401430

RESUMO

BACKGROUND: In general, cerebral blood flow accounts for 10-15% of cardiac output (CO), of which about 75% is delivered through the carotid arteries. Hence, if carotid blood flow (CBF) is constantly proportional to CO with high reproducibility and reliability, it would be of great value to measure CBF as an alternative to CO. The aim of this study was to investigate the direct correlation between CBF and CO. We hypothesized that measurement of CBF could be a good substitute for CO, even under more extreme hemodynamic conditions, for a wider range of critically ill patients. METHODS: Patients aged 65-80 years, undergoing elective cardiac surgery were included in this study. CBF in different cardiac cycles were measured by ultrasound: systolic carotid blood flow (SCF), diastolic carotid blood flow (DCF), and total (systolic and diastolic) carotid blood flow (TCF). CO simultaneously was measured by transesophageal echocardiography. RESULTS: For all patients, the correlation coefficients between SCF and CO, TCF and CO were 0.45 and 0.30, respectively, which were statistically significant, but not between DCF and CO. There was no significant correlation between either SCF, TCF or DCF and CO, when CO was <3.5 L/min. CONCLUSIONS: Systolic carotid blood flow may be used as a better index to replace CO. However, the method of direct measurement of CO is essential when the patient's heart function is poor.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Artérias Carótidas , Humanos , Reprodutibilidade dos Testes , Velocidade do Fluxo Sanguíneo/fisiologia , Artérias Carótidas/diagnóstico por imagem , Artérias Carótidas/cirurgia , Hemodinâmica , Débito Cardíaco/fisiologia , Circulação Cerebrovascular/fisiologia
15.
J R Soc Interface ; 20(204): 20230186, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37464803

RESUMO

ATP is not only an energy carrier but also serves as an important signalling molecule in many physiological processes. Abnormal ATP level in blood vessel is known to be related to several pathologies, such as inflammation, hypoxia and atherosclerosis. Using advanced numerical methods, we analysed ATP released by red blood cells (RBCs) and its degradation by endothelial cells (ECs) in a cat mesentery-inspired vascular network, accounting for RBC mutual interaction and interactions with vascular walls. Our analysis revealed a heterogeneous ATP distribution in the network, with higher concentrations in the cell-free layer, concentration peaks around bifurcations and heterogeneity among vessels of the same level. These patterns arise from the spatio-temporal organization of RBCs induced by the network geometry. It is further shown that an alteration of hematocrit and flow strength significantly affects ATP level as well as heterogeneity in the network. These findings constitute a first building block to elucidate the intricate nature of ATP patterns in vascular networks and the far reaching consequences for other biochemical signalling, such as calcium, by ECs.


Assuntos
Células Endoteliais , Eritrócitos , Células Endoteliais/metabolismo , Velocidade do Fluxo Sanguíneo/fisiologia , Eritrócitos/metabolismo , Microvasos/metabolismo , Trifosfato de Adenosina/metabolismo
16.
Eur J Cardiothorac Surg ; 63(6)2023 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-37280071

RESUMO

OBJECTIVES: (i) To monitor cerebral blood flow velocity (CBFv) throughout aortic arch repair surgery and during the recovery period. (ii) To examine the relationship between transcranial doppler ultrasound (TCD) and near-infrared spectroscopy (NIRS) during cardiac surgery. (iii) To examine CBFv in patients cooled to 20°C and 25°C. METHODS: During aortic arch repair and after surgery, measurements of TCD, NIRS, blood pH, pO2, pCO2, HCO3, lactate, Hb, haematocrit (%) and temperature (core and rectal) were recorded in 24 neonates. General linear mixed models were used to examine differences over time and between two cooling temperatures. Repeated measures correlations were used to determine the relationship between TCD and NIRS. RESULTS: CBFv changed during arch repair (main effect of time: P = 0.001). During cooling, CBFv increased by 10.0 cm/s (5.97, 17.7) compared to normothermia (P = 0.019). Once recovering in paediatric intensive care unit (PICU), CBFv had increased from the preoperative measurement by 6.2 cm/s (0.21, 13.4; P = 0.045). CBFv changes were similar between patients cooled to 20°C and 25°C (main effect of temperature: P = 0.22). Repeated measures correlations (rmcorr) identified a statistically significant but weak positive correlation between CBFv and NIRS (r = 0.25, P≤0.001). CONCLUSIONS: Our data suggested that CBFv changed throughout aortic arch repair and was higher during the cooling period. A weak relationship was found between NIRS and TCD. Overall, these findings could provide clinicians with information on how to optimise long-term cerebrovascular health.


Assuntos
Aorta Torácica , Ultrassonografia Doppler Transcraniana , Recém-Nascido , Criança , Humanos , Temperatura , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/cirurgia , Perfusão/métodos , Circulação Cerebrovascular/fisiologia , Velocidade do Fluxo Sanguíneo/fisiologia
17.
J Ultrasound Med ; 42(10): 2315-2330, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37209359

RESUMO

OBJECTIVES: Fabry disease (FD) is a rare X-linked lysosomal storage disorder with variable phenotypes, including neurological symptoms. These can be influenced by vascular impairment. Extracranial and transcranial vascular sonography is an effective and noninvasive method for measuring arterial structures and blood flow. The study aims to investigate cerebrovascular phenotype characteristics in FD patients compared to controls using neurosonology. METHODS: This is a single-center, cross-sectional study of 130 subjects-65 patients (38 females), with genetically confirmed FD, and 65 sex- and age-matched controls. Using ultrasonography, we measured structural and hemodynamic parameters, including distal common carotid artery intima-media thickness, inner vertebral artery diameter, resting blood flow velocity, pulsatility index, and cerebral vasoreactivity (CVR) in the middle cerebral artery. To assess differences between FD and controls and to identify factors influencing investigated outcomes, unadjusted and adjusted regression analyses were performed. RESULTS: In comparison to sex- and age-matched controls, FD patients displayed significantly increased carotid artery intima-media thickness (observed FD 0.69 ± 0.13 mm versus controls 0.63 ± 0.12 mm; Padj = .0014), vertebral artery diameter (observed FD 3.59 ± 0.35 mm versus controls 3.38 ± 0.33 mm; Padj = .0002), middle cerebral artery pulsatility index (observed FD 0.98 ± 0.19 versus controls 0.87 ± 0.11; Padj < .0001), and significantly decreased CVR (observed FD 1.21 ± 0.49 versus controls 1.35 ± 0.38; Padj = .0409), when adjusted by age, BMI, and sex. Additionally, FD patients had significantly more variable CVR (0.48 ± 0.25 versus 0.21 ± 0.14; Padj < .0001). CONCLUSIONS: Our results suggest the presence of multiple vascular abnormalities and changes in hemodynamic parameters of cerebral arteries in patients with FD.


Assuntos
Doença de Fabry , Feminino , Humanos , Doença de Fabry/diagnóstico por imagem , Espessura Intima-Media Carotídea , Estudos Transversais , Ultrassonografia , Hemodinâmica/fisiologia , Ultrassonografia Doppler Transcraniana/métodos , Velocidade do Fluxo Sanguíneo/fisiologia , Circulação Cerebrovascular/fisiologia
18.
J Cereb Blood Flow Metab ; 43(9): 1557-1570, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37070356

RESUMO

Quantification of vascularization volume can provide valuable information for diagnosis and prognosis in vascular pathologies. It can be adapted to inform the surgical management of gliomas, aggressive brain tumors characterized by exuberant sprouting of new blood vessels (neoangiogenesis). Filtered ultrafast Doppler data can provide two main parameters: vascularization index (VI) and fractional moving blood volume (FMBV) that clinically reflect tumor micro vascularization. Current protocols lack robust, automatic, and repeatable filtering methods. We present a filtrating method called Multi-layered Adaptive Neoangiogenesis Intra-Operative Quantification (MANIOQ). First, an adaptive clutter filtering is implemented, based on singular value decomposition (SVD) and hierarchical clustering. Second a method for noise equalization is applied, based on the subtraction of a weighted noise profile. Finally, an in vivo analysis of the periphery of the B-mode hyper signal area allows to measure the vascular infiltration extent of the brain tumors. Ninety ultrasound acquisitions were processed from 23 patients. Compared to reference methods in the literature, MANIOQ provides a more robust tissue filtering, and noise equalization allows for the first time to keep axial and lateral gain compensation (TGC and LGC). MANIOQ opens the way to an intra-operative clinical analysis of gliomas micro vascularization.


Assuntos
Neoplasias Encefálicas , Ultrassonografia Doppler , Humanos , Velocidade do Fluxo Sanguíneo/fisiologia , Imagens de Fantasmas , Ultrassonografia Doppler/métodos , Ultrassonografia , Neovascularização Patológica/diagnóstico por imagem , Neoplasias Encefálicas/diagnóstico por imagem , Neoplasias Encefálicas/cirurgia , Processamento de Imagem Assistida por Computador/métodos
19.
Comput Biol Med ; 158: 106805, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-37019010

RESUMO

Cardiovascular diseases are the leading cause of mortality in the world, mainly due to atherosclerosis and its consequences. The article presents the numerical model of the blood flow through artificial aortic valve. The overset mesh approach was applied to simulate the valve leaflets motion and to realize the moving mesh, in the aortic arch and the main branches of cardiovascular system. To capture the cardiac system's response and the effect of vessel compliance on the outlet pressure, the lumped parameter model has been also included within the solution procedure. Three different turbulence modeling approaches were used and compared - the laminar, k-ϵ and k-ω model. The simulation results were also compared with the model excluding the moving valve geometry and the importance of the lumped parameter model for the outlet boundary condition was analyzed. Proposed numerical model and protocol was found as suitable for performing the virtual operations on the real patient vasculature geometry. The time-efficient turbulence model and overall solving procedure allows to support the clinicians in making decisions about the patient treatment and to predict the results of the future surgery.


Assuntos
Valva Aórtica , Próteses Valvulares Cardíacas , Humanos , Valva Aórtica/cirurgia , Hemodinâmica , Resistência Vascular , Modelos Cardiovasculares , Velocidade do Fluxo Sanguíneo/fisiologia , Simulação por Computador
20.
J Clin Ultrasound ; 51(5): 860-865, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37029647

RESUMO

PURPOSE: Cholangitis after liver transplantation may lead to bile duct necrosis. Early diagnosis is essential to prevent graft loss. We aimed to investigate cholangitis related hepatic arterial Doppler ultrasonography findings in liver transplants. METHODS: Patients complicated with biopsy proven cholangitis in grafts were prospectively evaluated. Vascular complications were excluded. Doppler ultrasonography parameters including hepatic arterial diameter, resistive index, volume flow, and portal vein maximum velocity were measured twice: first during cholangitis and after full recovery. Data of two groups were compared using paired samples t test and Mann-Whitney U test. RESULTS: The mean hepatic arterial volume flow, resistive index, and diameter of 33 patients complicated with cholangitis was observed to decrease after recovery from 0.356 to 0.273 L/min (p = 0.007), from 0.64 to 0.60 (p < 0.001) and from 4.9 to 4.4 mm (p < 0.001), respectively. Portal vein maximum velocity alteration was not statistically significant (p = 0.6). CONCLUSION: Ultrasound follow-ups after liver transplantation can give us the clue of cholangitis initiation through some altering hepatic arterial Doppler parameters. Even though these are nonspecific findings that can also be observed in vascular complications, baseline Doppler data should be saved for future comparison and considered to prevent biliary associated graft loss.


Assuntos
Colangite , Transplante de Fígado , Humanos , Artéria Hepática/diagnóstico por imagem , Fígado/diagnóstico por imagem , Veia Porta/diagnóstico por imagem , Ultrassonografia Doppler , Colangite/complicações , Colangite/diagnóstico por imagem , Velocidade do Fluxo Sanguíneo/fisiologia